ReSolve ® locking biliary drainage catheter

Ask for information

ReSolve locking biliary drainage catheter have two different configuration - all with a large hole - and provide up to 4 times of drainage area for maximum drainage.ReSolve Biliary have radiopaque markers and radiopaque markers, in order to promote rapid accurate placement, noninvasive internal pigtail and hydrophilic coating, in order to realize the smooth insert and improve patient comfort.It allowed long-term indwelling time of polyurethane materials.

Video library

ReSolve ® locking biliary drainage catheter [abstract]

The characteristics and advantages

MR_ conditions Nuclear magnetic resonance (NMR) information
MR security under certain conditions

ReSolve + locking biliary drainage catheter is MR security under certain conditions

The clinical tests showed that ReSolve + locking biliary drainage catheter is MR security under certain conditions.After placed under the following conditions, can be immediately available for patients with security scan:

  • 3 tesla under static magnetic field
  • The largest space gradient magnetic field 4000 gauss/cm (40 T/m)
  • Report the biggest MR system, in the first stage of the MR system control operation mode, the whole body, on average, than the absorption rate (SAR) of 4 - W/kg

MRI related heating

Under the condition of the above definition of scanning, ReSolve + locking biliary drainage catheter after 2.3 minutes continuous scanning is expected to produce 15 ° C of maximum temperature rise.

Artifacts information

On the gradient echo pulse sequence of 3 Tesla saw the biggest artifact size relative to ReSolve + locking biliary drainage catheter shape size about 2 mm

Powerful drainage

ourReSolve locking biliary drainage catheterSpecially designed for rapid and smooth drainage, provide as much as 4 times of drainage area, has a number of big holes and configuration of different size.Other benefits include the depth of the rapid accurate positioning and opaque rays marking tape, aiming to reduce the possibility of damage to the duodenum of no wound and pigtail of the polyurethane materials allow long-term indwelling time.

  • Two drainage hole patterns, to adapt to the patients with multiple lesions position and different anatomical structures
  • The unique locking mechanism to prevent movement.
  • Repositioning tools to unlock and reset catheters.
  • Opaque ray markers help fast accurate positioning.

To solve - biliary lock - RBDC To solve - biliary lock - RBC

ReSolve locking biliary drainage catheter of different pass for distal lesions (RBDC options) and proximal lesion (RBC) to provide targeted drainage.

The document

Check the manual and instructions, learn about ReSolve ® locking biliary drainage catheter for more information.